122-Compression Load Cell
Model: C-122
The C-122 is a heavy duty general purpose compression load cell. The simple compact design and rugged hermetically sealed construction assures its long term life in all types of field installations.
The 122 load cell is often used in multi-cell installations, therefore its standard output tolerance is within 0.1%.
Typical Specification
| Parameter | Value | Units |
|---|---|---|
| Capacities Range | 50, 100, 150 | Te |
| Rated Output | 1.5 / 2 | mV/V |
| Linearity & non repeatability | 0.03 | ±% of Full Scale |
| Zero Return after 30 minutes | 0.05 | ±% of Applied Load |
| Zero Balance | 1.5 | ±% of Full Scale |
|
Temp. Range: Operating Temp. Range: Compensated |
-20 to +60 +5 to +45 |
°C |
|
Temp. Effect: On Output Temp. Effect: On zero |
0.008 0.005 |
±% of Full Scale ±% of Full Scale |
| Safe Overload | 150 | % of Rated Capacity |
| Ultimate Overload | 200 | % of Rated Capacity |
|
Excitation: Recommended Excitation: Maximum |
10 15 |
Volts AC or DC |
| Input Impedance | 670±15 / 1270±20 / 1350±30 | ohm |
| Output Impedance | 600±5 / 1205±5 / 1205±5 | ohm |
| Insulation Resistance | >2 | GΩ at 50VDC |
| Deflection at Rated Capacity | NA | mm |
| Weight (approximate) | NA | kg |
| Construction | Plated Alloy Steel | |
| Environmental Protection | IP65 | |
| Cable | 5m 4 core scr |
Outline Dimensions in millimeters
NOTE: If the dimensions or specification do not suit, PCM have an in-house design and build service that should satisfy your requirements.
Wiring Detail
Loading Mode
Modifications reserved. All details describe our products in general form only. PCM assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sales and/or use of PCM products including liability or warranties relating to fitness for a particular purpose.
Features
- Capacities 50—150Te
- Sealed to IP68
- Accuracy 0.03% RO
Applications
- Truck scales, weighbridges
- Hoppers for process control
- Tank and silo weighing
- Harsh environment