TLL-Tension Load Link
Model: T-TLL
The T-TLL is a tension load link mainly used in the crane / lifting industry for crane weighing or overload protection. The unit can be coupled with an indicator or a telemetry radio unit for ultimate mobility. If the dimensions or specifications do not satisfy your application, then please contact PCM and their in-house design and build service may be able to supply to your requirements.
Typical Specification
| PARAMETER | VALUE | UNITS |
|---|---|---|
| Capacities Range | 0… 5, 10, 25, 45 | Te |
| Rated Output | 1.5 nominal | mV/V |
| Linearity & non repeatability | 0.3 | ±% of Rated Output |
| Zero Return after 30 minutes | 0.15 | ±% of Applied Load |
| Zero Balance | 1.5 | ±mV/V |
| Temp. Range: Operating Temp. Range: Compensated |
-30 to +80 -10 to +60 |
°C |
| Temp. Effect: On Output Temp. Effect: On zero |
0.1 0.02 |
±% of Applied Load/°C ±% of Rated Load/°C |
| Safe Overload | 200 | % of Rated Capacity |
| Ultimate Overload | 500 | % of Rated Capacity |
| Excitation: Recommended Excitation: Maximum |
10 18 |
Volts AC or DC |
| Input Impedance | 350 nominal | ohm |
| Output Impedance | 350 nominal | ohm |
| Insulation Resistance | >2 | GΩ at 50VDC |
| Deflection at Rated Capacity | N/A | mm |
| Weight (approximate) | N/A | kg |
| Construction | Plated Alloy Steel | |
| Environmental Protection | IP67 | |
| Cable | 5m 4 core scr |
Outline Dimensions in millimeters

NOTE: If the dimensions or specification do not suit, PCM have an in-house design and build service that should satisfy your requirements.
Wiring Detail

Loading Mode

Modifications reserved. All details describe our products in general form only. PCM assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sales and/or use of PCM products including liability or warranties relating to fitness for a particular purpose.
Features
- Capacities 5-45Te
- Sealed to IP67
- Tension use
- Custom build dimensions available
Applications
- Overload protection
- Crane weighing
- Test rigs