Strain Gauge Bolt Sensor
Model: S-SGBS
The S-SGBS is a strain gauged bolt. There are two options: -
(i) Externally strain gauged: This is done by reducing the outer diameter on the shank of the bolt and applying a full bridge to this reduced area
(ii) Internally strain gauged: This is done by spark eroding a 1.6mm hole down the centre of the bolt and applying a single strain gauge on the neutral axis.
The build specification will be established during the quotation stage as there are plenty of options available.
The bolts can be load calibrated using PCM’s calibration facility.
Typical Specification
| PARAMETER | VALUE | UNITS |
|---|---|---|
| Capacities Range | To suit the bolt size | µε |
| Rated Output | Dependant on bolt size and diameter | mV/V |
| Linearity & non repeatability | Typically 0.25% depending on bolt quality | ±% of Rated Output |
| Zero Return after 30 minutes | 0.15 | ±% of Applied Load |
| Zero Balance | 1.5 | ±% of Rated Output |
| Temp. Range: Operating | -30 to +80 | °C |
| Temp. Effect: On zero | 0.2 | µV/V/°C |
| Safe Overload | 150 | % of Rated Capacity |
| Ultimate Overload | 300 | % of Rated Capacity |
| Excitation: Recommended Excitation: Maximum |
10 15 |
Volts AC or DC |
| Input Impedance | 120—350 nominal | ohm |
| Output Impedance | 120—350 nominal | ohm |
| Insulation Resistance | >2 | GΩ at 50VDC |
| Deflection at Rated Capacity | NA | mm |
| Weight (approximate) | NA | kg |
| Construction | Steel—depending on bolt | |
| Environmental Protection | IP65 | |
| Cable | Optional |
Features
- 1/4, 1/2 or full bridge
- Sealed to IP65
- Built to order
Applications
- Test rigs
- Research and development
- Where there is limited space where traditional load cells cannot be used