D100-Tension Link
Model: T-TL-D100
The T-TL-D100 provides a simple device for tension measurement.
The D100 is produced from stainless steel construction and is a laser welded assembly.
The load cell has been designed for lifting applications.
Typical Specification
| PARAMETER | VALUE | UNITS |
|---|---|---|
| Capacities Range | 20, 30, 50, 75, 100 | Te |
| Rated Output | 1.0 ±0.001 | mV/V |
| Linearity & non repeatability | 0.1 | ±% of Rated Output |
| Zero Return after 30 minutes | 1.0 | ±% of Rated Output |
| Zero Balance | 1.0 | ±% of Rated Output |
| Temp. Range: Operating Temp. Range: Compensated |
-20 to +70 -10 to +40 |
°C |
| Temp. Effect: On Output Temp. Effect: On zero |
0.008 0.028 |
±% of Rated Output/°C ±% of Rated Load/°C |
| Safe Overload | 150 | % of Rated Capacity |
| Ultimate Overload | 500, 400, 300, 200 | % of Rated Capacity |
| Excitation: Recommended Excitation: Maximum |
10 18 |
Volts AC or DC |
| Input Impedance | 420 ±20 | ohm |
| Output Impedance | 350 ±2 | |
| Insulation Resistance | >5 | GΩ at 50VDC |
| Deflection at Rated Capacity | NA | mm |
| Weight (approximate) | ˜11, ˜19 | kg |
| Construction | Stainless Steel | |
| Environmental Protection | IP65 | |
| Cable | Connector |
Outline Dimensions in millimeters

NOTE: If the dimensions or specification do not suit, PCM have an in-house design and build service that should satisfy your requirements.
Wiring Detail

Loading Mode

Modifications reserved. All details describe our products in general form only. PCM assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sales and/or use of PCM products including liability or warranties relating to fitness for a particular purpose.
Features
- Capacities 0.5-9.5Te
- Sealed to IP20
- Tension use
- Accuracy 0.05% FS
Applications
- Lifting devices
- Bridge cranes
- Process Control